Emissivity compensated spectral pyrometry-algorithm and sensitivity analysis
Artikel i vetenskaplig tidskrift, 2014

In order to solve the problem of non-contact temperature measurements on an object with varying emissivity, a new method is herein described and evaluated. The method uses spectral radiance measurements and converts them to temperature readings. It proves to be resilient towards changes in spectral emissivity and tolerates noisy spectral measurements. It is based on an assumption of smooth changes in emissivity and uses historical values of spectral emissivity and temperature for estimating current spectral emissivity. The algorithm, its constituent steps and accompanying parameters are described and discussed. A thorough sensitivity analysis of the method is carried out through simulations. No rigorous instrument calibration is needed for the presented method and it is therefore industrially tractable.

temperature

ANALYTICAL CHEMISTRY

DIFFERENTIATION

emissivity

spectrophotometer

multispectral pyrometry

varying emissivity

1972

EINIER J

P1906

V44

Författare

Petter Hagqvist

Hogskolan Vast

Fredrik Sikström

Hogskolan Vast

Anna-Karin Christiansson

Hogskolan Vast

Bengt Lennartson

Chalmers, Signaler och system, System- och reglerteknik

Measurement Science and Technology

0957-0233 (ISSN) 1361-6501 (eISSN)

Vol. 25 2

Ämneskategorier (SSIF 2011)

Elektroteknik och elektronik

DOI

10.1088/0957-0233/25/2/025011

Mer information

Skapat

2017-10-07