Impact of Periodic Current Pulses on Li-Ion Battery Performance
Journal article, 2012

Pulse charging and pulse discharging have been reported by many authors in the literature to improve the performance of various secondary electrochemical cells. Only a few authors mentioned the effects of such charge and discharge method on lithium-ion batteries. The overall objective of this work is to experimentally investigate the impact of certain current pulse profiles on the electrical performance of Li-ion batteries. The results highlight a detrimental impact of periodic pulses on the cell performance compared to profiles with constant current.

Current pulses

electrical performance

positive plate

charge

energy storage system

pv applications

lead-acid-batteries

lithium-ion

Author

F. Savoye

Volvo Technology Corporation

Universite de Lyon

P. Venet

Universite de Lyon

M. Millet

Volvo Technology Corporation

Jens Groot

Chalmers, Energy and Environment, Electric Power Engineering

IEEE Transactions on Industrial Electronics

0278-0046 (ISSN)

Vol. 59 9 3481-3488

Subject Categories (SSIF 2011)

Electrical Engineering, Electronic Engineering, Information Engineering

Other Electrical Engineering, Electronic Engineering, Information Engineering

DOI

10.1109/TIE.2011.2172172

More information

Created

10/6/2017